Compaq ProLiant 6400R Compaq Parallel Database Cluster Model PDC/O1000 for Ora

Summary of contents

  • Compaq Parallel Database Cluster Model PDC/O1000 for Oracle8i and Windows 2000 Administrator Guide
  • Notice
  • Contents
  • About This Guide
    • Purpose
    • Audience
    • Scope
    • Referenced Manuals
    • Supplemental Documents
    • Text Conventions
    • Symbols in Text
    • Symbols on Equipment
    • Rack Stability
    • Getting Help
      • Compaq Technical Support
      • Compaq Website
      • Compaq Authorized Reseller
  • Chapter 1: Clustering Overview
    • Clusters Defined
    • Availability
    • Scalability
    • Compaq Parallel Database Cluster Overview
  • Chapter 2: Architecture
    • Compaq ProLiant Servers
      • High\x1EAvailability Features of ProLiant Servers
    • Shared Storage Components
      • RA4000 Array
      • RA4100 Array
      • RA4000 Array Controller
      • Fibre Channel SAN Switch
      • Storage Hub
      • FC\x1EAL Switch
      • Fibre Host Adapters
      • Gigabit Interface Converter-Shortwave Modules
      • Fibre Channel Cables
      • Availability Features of the Shared Storage Components
    • I/O Path Configurations in a Non\x1ERedundant Fibre Channel Fabric
      • Overview of Fibre Channel Fabric SAN Topology
      • Non-Redundant Fibre Channel Fabric
      • Using Multiple Non\x1ERedundant Fibre Channel Fabrics
      • Maximum Distances Between Cluster Nodes and Shared Storage Subsystem Components in a Non\x1ERedundant Fibre Channel Fabric
      • I/O Data Paths for a Non\x1ERedundant Fibre Channel Fabric
        • Fibre Host Adapter-to-Fibre Channel SAN Switch Paths
        • Fibre Channel SAN Switch-to-Array Controller Paths
    • I/O Path Configurations in a Non\x1ERedundant Fibre Channel Arbitrated Loop
      • Overview of FC\x1EAL SAN Topology
      • Non-Redundant Fibre Channel Arbitrated Loop
      • Using Multiple Non-Redundant Fibre Channel Arbitrated Loops
      • Maximum Distances Between Cluster Nodes and Shared Storage Subsystem Components in a Non\x1ERedundant FC\x1EAL
      • I/O Data Paths for a Non-Redundant FC-AL
        • Fibre Host Adapter-to-Storage Hub/FC\x1EAL Switch Paths
        • Storage Hub/FC-AL Switch-to-Array Controller Paths
    • Cluster Interconnect Options
      • Ethernet Cluster Interconnect
        • Non-Redundant Ethernet Cluster Interconnect Components
        • Redundant Ethernet Cluster Interconnect Components
        • Ethernet Cluster Interconnect Adapters
        • Ethernet Switch
        • Ethernet Cluster Interconnect Diagrams
      • Local Area Network
  • Chapter 3: Cluster Software Components
    • Overview of the Cluster Software
    • Microsoft Windows 2000 Advanced Server
    • Compaq Software
      • Compaq SmartStart and Support Software
      • Compaq System Configuration Utility
      • Compaq Array Configuration Utility
      • Fibre Channel Fault Isolation Utility
      • Compaq Insight Manager
      • Compaq Insight Manager XE
      • Compaq Options ROMPaq
      • Compaq Operating System Dependent Modules
        • OSDs for Oracle8i Parallel Server
    • Oracle Software
      • Oracle8i Server Enterprise Edition
      • Oracle8i Server
      • Oracle8i Parallel Server Option
      • Oracle8i Enterprise Manager
      • Oracle8i Certification
    • Application Failover and Reconnection Software
  • Chapter 4: Cluster Planning
    • Site Planning
    • Capacity Planning for Cluster Hardware
      • Compaq ProLiant Servers
      • Planning Shared Storage Components for Non\x1ERedundant Fibre Channel Fabrics
      • Planning Shared Storage Components for Non\x1ERedundant Fibre Channel Arbitrated Loops
      • Planning Cluster Interconnect and Client LAN Components
        • Planning an Ethernet Cluster Interconnect
        • Planning the Client LAN
    • Planning Cluster Configurations for Non\x1ERedundant Fibre Channel Fabrics
      • Sample Midsize Cluster with One Non\x1ERedundant Fibre Channel Fabric
      • Sample Large Cluster with One Non-Redundant Fibre Channel Fabric
    • Planning Cluster Configurations for Non\x1ERedundant Fibre Channel Arbitrated Loops
      • Sample Midsize Cluster with One Non\x1ERedundant FC\x1EAL
      • Sample Large Cluster with One Non-Redundant FC\x1EAL
    • RAID Planning
      • Supported RAID Levels
      • Raw Data Storage and Database Size
      • Selecting the Appropriate RAID Levels
    • Planning the Grouping of Physical Disk Storage Space
    • Disk Drive Planning
      • Nonshared Disk Drives
      • Shared Disk Drives
    • Network Planning
      • Windows 2000 Advanced Server Hosts Files for an Ethernet Cluster Interconnect
      • Client LAN
  • Chapter 5: Installation and Configuration
    • Installation Overview
    • Installing the Hardware
      • Setting Up the Nodes
      • Installing the Fibre Host Adapters
      • Installing GBIC-SW Modules for the Fibre Host Adapters
      • Cabling the Fibre Host Adapters to the Storage Hub, FC-AL Switch, or Fibre Channel SAN Switch
      • Installing the Cluster Interconnect Adapters
        • Ethernet Cluster Interconnect Adapters
      • Installing the Client LAN Adapters
      • Setting Up the RA4000/RA4100 Arrays
        • Compaq Array Configuration Utility
      • Installing GBIC-SW Modules for the RA4000 Array Controller
      • Cabling the Storage Hub, FC-AL Switch, or Fibre Channel SAN Switch to the RA4000 Array Controllers
      • Installing Additional Fibre Channel Fabrics or FC\x1EALs
      • Cabling the Ethernet Cluster Interconnect
      • Cabling the Client LAN
        • Redundant Client LAN
    • Installing Operating System Software and Configuring the RA4000/RA4100 Arrays
      • Guidelines for Clusters
      • Automated Installation Using SmartStart
        • Cluster-Specific SmartStart Installation
        • Automated Installation Steps
    • Installing Compaq OSDs
      • Verifying Cluster Communications
      • Mounting Remote Drives and Verifying Administrator Privileges
      • Installing the Ethernet OSDs
    • Installing Oracle Software
    • Configuring Oracle Software
    • Installing Object Link Manager
      • Additional Notes on Configuring Oracle Software
        • Creating a Symbolic Link for OPS_CMDISK
        • Verifying Access to Shared Storage from All Nodes
    • Verifying the Hardware and Software Installation
      • Cluster Communications
      • Access to Shared Storage from All Nodes
      • OSDs
      • Other Verification Tasks
    • Power Distribution and Power Sequencing Guidelines
      • Server Power Distribution
      • RA4000/RA4100 Array Power Distribution
      • Power Sequencing
  • Chapter 6: Cluster Management
    • Cluster Management Concepts
      • Powering Off a Node Without Interrupting Cluster€Services
      • Managing a Cluster in a Degraded Condition
      • Managing Network Clients Connected to a Cluster
      • Cluster Events
    • Management Applications
      • Monitoring Server and Network Hardware
      • Managing Shared Drives
      • Monitoring Non\x1ERedundant Fibre Channel Fabrics
      • Monitoring Non\x1ERedundant Fibre Channel Arbitrated Loops
      • Monitoring the Database
      • Remotely Managing a Cluster
    • Software Maintenance for Oracle8i
      • Deinstalling the OSDs
      • Upgrading Oracle8i Server
      • Upgrading the OSDs
        • Upgrading the Ethernet OSDs
      • Deinstalling a Partial OSD Installation
      • Upgrading Oracle8i Server
    • Managing Changes to Shared Storage Components
      • Replacing a Failed Disk
      • Adding Disk Drives to Increase Shared Storage Capacity
      • Adding an RA4000/RA4100 Array
      • Replacing a Failed Fibre Host Adapter
    • Replacing a Cluster Node
      • Removing the Node
      • Adding the Replacement Node
        • Preparing the Replacement Node
        • Installing the Cluster Software
    • Adding a Cluster Node
      • Preparing the New Node
      • Preparing the Existing Cluster Nodes
      • Installing the Cluster Software for Oracle8i
    • Monitoring Cluster Operation
      • Tools Overview
  • Chapter 7: Troubleshooting
    • Basic Troubleshooting Tips
      • Power
      • Physical Connections
      • Access to Cluster Components
      • Software Revisions
      • Firmware Revisions
    • Troubleshooting Oracle8i and OSD Installation Problems and Error Messages
      • Potential Difficulties Installing the OSDs with the Oracle Universal Installer
      • Unable to Start OracleCMService
      • Unable to Start OracleNMService
      • Unable to Start the Database
      • Initialization of the Dynamic Link Library NM.DLL Failed
    • Troubleshooting Node-to-Node Connectivity Problems
      • Nodes Are Unable to Communicate with Each Other
        • When Using an Ethernet Cluster Interconnect
      • Unable to Ping the Cluster Interconnect or the Client LAN
        • When Using an Ethernet Cluster Interconnect
      • Node or Nodes Unable to Rejoin the Cluster
    • Troubleshooting Client-to-Cluster Connectivity Problems
      • A Network Client Cannot Communicate with the Cluster
    • Troubleshooting Shared Storage Problems
      • Verifying Connectivity to a Non\x1ERedundant Fibre Channel Fabric
      • Verifying Connectivity to a Non\x1ERedundant Fibre Channel Arbitrated Loop
      • Shared Disks in the RA4000/RA4100 Arrays Are Not Recognized By One or More Nodes
      • A Cluster Node Cannot Connect to the Shared Drives
  • Appendix A: Diagnosing and Resolving Shared Disk Problems
    • Introduction
    • Run Object Link Manager On All Nodes
    • Restart All Affected Nodes in the Cluster
    • Rerun and Validate Object Link Manager On All Affected Nodes
    • Run Disk Management On All Nodes
    • Run and Validate the Array Configuration Utility On All Nodes
    • Perform Cluster Software and Firmware Checks
    • Perform Cluster Hardware Checks
    • Contact Your Compaq Support Representative
  • Glossary
  • Index
pdf background image
download button

Related manuals