Fujitsu IRMC-S2-S3 manual
Summary of contents
- Contents
- Preface
- Purpose and target groups of the manual
- Functions of the iRMC S2/S3 (overview)
- Communication interfaces of the iRMC S2/S3
- Communication protocols used by the iRMC S2/S3
- IPMI - technical background
- DCMI (Data Center Management Interface)
- Changes since the previous versions of the manual
- ServerView Suite link collection
- Documentation for ServerView Suite
- Notational conventions
- Logging on to the iRMC S2/S3 for the first time
- Requirements
- iRMC S2/S3 factory defaults
- Logging into the iRMC S2/S3 web interface
- Configuring the iRMC S2/S3
- Configuring the LAN interface of the iRMC S2/S3
- Prerequisites
- Connected to the correct LAN port?
- Interaction between the IP addresses of the iRMC S2/S3 and the system
- Access from a different subnet
- Configuring the LAN interface: Configuration tools
- Configuring the LAN interface using the BIOS / TrustedCore / UEFI setup utility
- Configuring the LAN interface of the iRMC S2 by using the BIOS / TrustedCore setup utility
- Configuring the LAN interface of the iRMC S3 by using the UEFI setup Utility
- Testing the LAN interface
- Configuring text console redirection via LAN using the BIOS / TrustedCore / UEFI setup utility
- Configuring text console redirection for the iRMC S2
- Configuring text console redirection for the iRMC S3
- Using console redirection while the operating system is running
- Configuring and using the serial interface of the iRMC S2/S3
- Configuring the serial interface of the iRMC S2
- Configuring the serial interface using of the iRMC S3
- Using the Remote Manager (Serial) interface
- Configuring the iRMC S2/S3 over the iRMC S2/S3 web interface
- Configuring the LAN parameters
- Configuring alerting
- Configuring text console redirection
- User management for the iRMC S2/S3
- User management concept for the iRMC S2/S3
- User permissions
- Local user management for the iRMC S2/S3
- Local user management using the iRMC S2/S3 web interface
- Local user management via the Server Configuration Manager
- SSHv2 public key authentication for iRMC S2/S3 users
- reating public and private SSHv2 keys
- Loading the public SSHv2 key onto the iRMC S2/S3 from a file
- Configuring PuTTY and the OpenSSH client for using the public SSHv2 key
- Example: Public SSHv2 key
- Advanced Video Redirection (AVR)
- Requirements: Check the AVR settings
- Using AVR
- Using a low bandwidth
- Parallel AVR sessions
- Local Monitor Off\
- Redirecting the keyboard
- Redirecting the mouse
- Synchronizing the mouse pointer
- Managed Windows server: Adjusting the settings for synchronization of the mouse pointers
- Managed Linux server: Adjusting the settings for synchronization of the mouse pointers
- Menus of the AVR window
- Extras menu
- Remote Storage menu
- Power Control menu
- Languages menu
- Preferences menu
- Remote Storage
- Providing remote storage at the remote workstation
- Starting Remote Storage
- Provision of storage media for emote Storage
- Connecting storage media as remote storage
- Clearing Remote Storage connections
- Removing the storage medium
- Providing remote storage via a Remote Storage server
- Installing the Remote Storage server
- Remote Storage server execution modes
- Configuring, starting and exiting the Remote Storage server
- iRMC S2/S3 web interface
- Logging into the iRMC S2/S3 web interface
- Required user permissions
- Structure of the user interface
- System Information - Information on the server
- System Overview - General information on the server
- System Component Information - Information on the server components
- BIOS - Backing up/restore BIOS settings, flashing BIOS
- Backup/Restoration - Saving/Restoring BIOS single parameter settings to/from a file
- Backing up single BIOS parameters in ServerView® WinSCU XML format
- Restoring single BIOS parameters in ServerView® WinSCU XML format
- BIOS - Updating BIOS via \
- iRMC S2/S3 - Information, firmware and certificates
- iRMC S2/S3 Information - Information on the iRMC S2/S3
- Save iRMC S2/S3 Firmware Settings - Save firmware settings
- Certificate Upload - Load the DSA/RSA certificate and private DSA/RSA key
- Generate a self-signed Certificate - Generate self-signed RSA certificate
- iRMC S2/S3 Firmware Update
- Power Management
- Power On/Off - power the server up/down
- Power Options - Configuring power management for the server
- Power Supply Info - Power supply and IDPROM data for the FRU components
- Power Consumption
- Power Consumption Configuration - Configure power consumption of the server
- Current Power Consumption - Show the current power consumption
- Power Consumption History - Show server power consumption
- Sensors - Check status of the sensors
- Fans - Check fans
- Temperature - Report the temperature of the server components
- Voltages - Report voltage sensor information
- Power Supply - Check power supply
- Component Status - Check status of the server components
- System Event Log and Internal Event Log
- System Event Log Content - Show information on the SEL and the SEL entries
- Internal Event Log Content - Show information on the internal eventlog and the associated entries
- Event Log Configuration - Configure IPMI SEL and internal event log
- Server Management Information - Configuring the server settings
- Network Settings - Configure the LAN parameters
- Network Interface Settings - Configure Ethernet settings on the iRMC S2/S3
- Ports and Network Services - Configuring ports and network services
- DNS Configuration - Configuring DNS for the iRMC S2/S3
- Alerting - Configure alerting
- SNMP Trap Alerting - Configure SNMP trap alerting
- Serial / Modem Alerting - Configure alerting via modem
- Email Alerting - Configure email alerting
- User Management
- iRMC S2/S3 User - local user management on the iRMC S2/S3
- New User Configuration - Configuring a new user
- User “<name>” Configuration - User configuration (details)
- Directory Service Configuration (LDAP) - Configuring the directory service at the iRMC S2/S3
- Configuring iRMC S2/S3 for Microsoft Active Directory
- Configuring iRMC S2/S3 for Novell eDirectory / OpenLDAP / OpenDS
- Centralized Authentication Service (CAS) Configuration - Configuring the CAS Service
- Console Redirection - Redirecting the console
- BIOS Text Console - Configure and start text console redirection
- BIOS Console Redirection Options - Configure text console redirection
- Text Console Redirection (via Serial over LAN) - Start text console redirection
- Text console redirection while the operating system is running
- Advanced Video Redirection - Start Advanced Video Redirection (AVR)
- Remote Storage
- Operating iRMC S2/S3 via Telnet / SSH (Remote Manager)
- iRMC S2/S3 via Telnet/SSH (Remote Manager)
- Requirements on the managed server
- Operating Remote Manager
- Overview of menus
- Logging in
- Main menu of the Remote Manager
- Required user permissions
- Change the password
- System Information - Information on the managed server
- Power Management
- Enclosure Information - System event log and status of the sensors
- Service processor - IP parameters, identification LED and iRMC S2/S3 reset
- Console Redirection (EMS/SAC) - Start text console redirection
- Start a Command Line shell... - Start a SMASH CLP shell
- Console Logging - Redirect message output to the text console (serial)
- Command Line Protocol (CLP)
- Configuring iRMC S2/S3 using the Server Configuration Manager
- Calling the Server Configuration Manager from the ServerView Installation Manager
- Calling the Server Configuration Manager from the Windows Start menu
- alling the Server Configuration Manager from the Operations Manager
- Firmware update
- iRMC S2/S3 firmware (overview)
- Setting up the USB memory stick
- Updating firmware images
- Update via the iRMC S2/S3 web interface
- Update using the ServerView Update Manager
- Online update using ServerView Update Manager Express or ASP
- Update using the operating system flash tools.
- Update via the lashDisk menu
- Emergency flash
- Flash tools
- Remote installation of the operating system via iRMC S2/S3
- Installing the operating system via iRMC S2/S3 - general procedure
- Connecting a storage medium as remote storage
- Booting the managed server from ServerView Suite DVD 1 and configuring it with the Installation Manager
- Installing the operating system on the managed server after configuration
- Installing Windows on the managed server after configuration
- Installing Linux on the managed server after configuration
- Appendix
- IPMI OEM Commands supported by the iRMC S2/S3
- Overview
- Description of the IPMI OEM commands
- Description format
- SCCI-compliant Power On/Off commands
- SCCI-compliant communication commands
- SCCI-compliant signaling command
- Firmware-specific commands
- BIOS-specific commands
- iRMC S2/S3-specific commands
- Configuring the iRMC S2/S3 via SCCI and scripted configuration
- iRMC S2/S3 configuration data
- Overview
- SCCI file format
- Restrictions
- Exporting / importing configuration data from / on the iRMC S2/S3
- Scripted configuration of the iRMC S2/S3
- List of SCCI commands supported by the iRMC S2/S3
- Scripting with cURL
- Scripting with Visual Basic (VB) Script
- Scripting with Python
- Generating encrypted passwords with iRMC_PWD.exe