Fujitsu IRMC-S2-S3 manual

Summary of contents

  • Contents
  • Preface
    • Purpose and target groups of the manual
    • Functions of the iRMC S2/S3 (overview)
    • Communication interfaces of the iRMC S2/S3
    • Communication protocols used by the iRMC S2/S3
    • IPMI - technical background
    • DCMI (Data Center Management Interface)
    • Changes since the previous versions of the manual
    • ServerView Suite link collection
    • Documentation for ServerView Suite
    • Notational conventions
  • Logging on to the iRMC S2/S3 for the first time
    • Requirements
    • iRMC S2/S3 factory defaults
    • Logging into the iRMC S2/S3 web interface
  • Configuring the iRMC S2/S3
    • Configuring the LAN interface of the iRMC S2/S3
      • Prerequisites
        • Connected to the correct LAN port?
        • Interaction between the IP addresses of the iRMC S2/S3 and the system
        • Access from a different subnet
      • Configuring the LAN interface: Configuration tools
      • Configuring the LAN interface using the BIOS / TrustedCore / UEFI setup utility
        • Configuring the LAN interface of the iRMC S2 by using the BIOS / TrustedCore setup utility
        • Configuring the LAN interface of the iRMC S3 by using the UEFI setup Utility
      • Testing the LAN interface
    • Configuring text console redirection via LAN using the BIOS / TrustedCore / UEFI setup utility
      • Configuring text console redirection for the iRMC S2
      • Configuring text console redirection for the iRMC S3
      • Using console redirection while the operating system is running
    • Configuring and using the serial interface of the iRMC S2/S3
      • Configuring the serial interface of the iRMC S2
      • Configuring the serial interface using of the iRMC S3
      • Using the Remote Manager (Serial) interface
    • Configuring the iRMC S2/S3 over the iRMC S2/S3 web interface
      • Configuring the LAN parameters
      • Configuring alerting
      • Configuring text console redirection
  • User management for the iRMC S2/S3
    • User management concept for the iRMC S2/S3
    • User permissions
    • Local user management for the iRMC S2/S3
      • Local user management using the iRMC S2/S3 web interface
      • Local user management via the Server Configuration Manager
      • SSHv2 public key authentication for iRMC S2/S3 users
        • reating public and private SSHv2 keys
        • Loading the public SSHv2 key onto the iRMC S2/S3 from a file
        • Configuring PuTTY and the OpenSSH client for using the public SSHv2 key
        • Example: Public SSHv2 key
  • Advanced Video Redirection (AVR)
    • Requirements: Check the AVR settings
    • Using AVR
      • Using a low bandwidth
      • Parallel AVR sessions
      • Local Monitor Off\
      • Redirecting the keyboard
      • Redirecting the mouse
        • Synchronizing the mouse pointer
        • Managed Windows server: Adjusting the settings for synchronization of the mouse pointers
        • Managed Linux server: Adjusting the settings for synchronization of the mouse pointers
    • Menus of the AVR window
      • Extras menu
      • Remote Storage menu
      • Power Control menu
      • Languages menu
      • Preferences menu
  • Remote Storage
    • Providing remote storage at the remote workstation
      • Starting Remote Storage
      • Provision of storage media for emote Storage
      • Connecting storage media as remote storage
      • Clearing Remote Storage connections
      • Removing the storage medium
    • Providing remote storage via a Remote Storage server
      • Installing the Remote Storage server
      • Remote Storage server execution modes
      • Configuring, starting and exiting the Remote Storage server
  • iRMC S2/S3 web interface
    • Logging into the iRMC S2/S3 web interface
    • Required user permissions
    • Structure of the user interface
    • System Information - Information on the server
      • System Overview - General information on the server
      • System Component Information - Information on the server components
    • BIOS - Backing up/restore BIOS settings, flashing BIOS
      • Backup/Restoration - Saving/Restoring BIOS single parameter settings to/from a file
        • Backing up single BIOS parameters in ServerView® WinSCU XML format
        • Restoring single BIOS parameters in ServerView® WinSCU XML format
      • BIOS - Updating BIOS via \
    • iRMC S2/S3 - Information, firmware and certificates
      • iRMC S2/S3 Information - Information on the iRMC S2/S3
      • Save iRMC S2/S3 Firmware Settings - Save firmware settings
      • Certificate Upload - Load the DSA/RSA certificate and private DSA/RSA key
      • Generate a self-signed Certificate - Generate self-signed RSA certificate
      • iRMC S2/S3 Firmware Update
    • Power Management
      • Power On/Off - power the server up/down
      • Power Options - Configuring power management for the server
      • Power Supply Info - Power supply and IDPROM data for the FRU components
    • Power Consumption
      • Power Consumption Configuration - Configure power consumption of the server
      • Current Power Consumption - Show the current power consumption
      • Power Consumption History - Show server power consumption
    • Sensors - Check status of the sensors
      • Fans - Check fans
      • Temperature - Report the temperature of the server components
      • Voltages - Report voltage sensor information
      • Power Supply - Check power supply
      • Component Status - Check status of the server components
    • System Event Log and Internal Event Log
      • System Event Log Content - Show information on the SEL and the SEL entries
      • Internal Event Log Content - Show information on the internal eventlog and the associated entries
      • Event Log Configuration - Configure IPMI SEL and internal event log
    • Server Management Information - Configuring the server settings
    • Network Settings - Configure the LAN parameters
      • Network Interface Settings - Configure Ethernet settings on the iRMC S2/S3
      • Ports and Network Services - Configuring ports and network services
      • DNS Configuration - Configuring DNS for the iRMC S2/S3
    • Alerting - Configure alerting
      • SNMP Trap Alerting - Configure SNMP trap alerting
      • Serial / Modem Alerting - Configure alerting via modem
      • Email Alerting - Configure email alerting
    • User Management
      • iRMC S2/S3 User - local user management on the iRMC S2/S3
        • New User Configuration - Configuring a new user
        • User “<name>” Configuration - User configuration (details)
      • Directory Service Configuration (LDAP) - Configuring the directory service at the iRMC S2/S3
        • Configuring iRMC S2/S3 for Microsoft Active Directory
        • Configuring iRMC S2/S3 for Novell eDirectory / OpenLDAP / OpenDS
      • Centralized Authentication Service (CAS) Configuration - Configuring the CAS Service
    • Console Redirection - Redirecting the console
      • BIOS Text Console - Configure and start text console redirection
        • BIOS Console Redirection Options - Configure text console redirection
        • Text Console Redirection (via Serial over LAN) - Start text console redirection
        • Text console redirection while the operating system is running
      • Advanced Video Redirection - Start Advanced Video Redirection (AVR)
    • Remote Storage
    • Operating iRMC S2/S3 via Telnet / SSH (Remote Manager)
  • iRMC S2/S3 via Telnet/SSH (Remote Manager)
    • Requirements on the managed server
    • Operating Remote Manager
    • Overview of menus
    • Logging in
    • Main menu of the Remote Manager
    • Required user permissions
    • Change the password
    • System Information - Information on the managed server
    • Power Management
    • Enclosure Information - System event log and status of the sensors
    • Service processor - IP parameters, identification LED and iRMC S2/S3 reset
    • Console Redirection (EMS/SAC) - Start text console redirection
    • Start a Command Line shell... - Start a SMASH CLP shell
    • Console Logging - Redirect message output to the text console (serial)
    • Command Line Protocol (CLP)
  • Configuring iRMC S2/S3 using the Server Configuration Manager
    • Calling the Server Configuration Manager from the ServerView Installation Manager
    • Calling the Server Configuration Manager from the Windows Start menu
    • alling the Server Configuration Manager from the Operations Manager
  • Firmware update
    • iRMC S2/S3 firmware (overview)
    • Setting up the USB memory stick
    • Updating firmware images
      • Update via the iRMC S2/S3 web interface
      • Update using the ServerView Update Manager
      • Online update using ServerView Update Manager Express or ASP
      • Update using the operating system flash tools.
      • Update via the lashDisk menu
    • Emergency flash
    • Flash tools
  • Remote installation of the operating system via iRMC S2/S3
    • Installing the operating system via iRMC S2/S3 - general procedure
    • Connecting a storage medium as remote storage
    • Booting the managed server from ServerView Suite DVD 1 and configuring it with the Installation Manager
    • Installing the operating system on the managed server after configuration
      • Installing Windows on the managed server after configuration
      • Installing Linux on the managed server after configuration
  • Appendix
    • IPMI OEM Commands supported by the iRMC S2/S3
      • Overview
      • Description of the IPMI OEM commands
        • Description format
        • SCCI-compliant Power On/Off commands
        • SCCI-compliant communication commands
        • SCCI-compliant signaling command
        • Firmware-specific commands
        • BIOS-specific commands
        • iRMC S2/S3-specific commands
    • Configuring the iRMC S2/S3 via SCCI and scripted configuration
      • iRMC S2/S3 configuration data
        • Overview
        • SCCI file format
        • Restrictions
        • Exporting / importing configuration data from / on the iRMC S2/S3
      • Scripted configuration of the iRMC S2/S3
        • List of SCCI commands supported by the iRMC S2/S3
        • Scripting with cURL
        • Scripting with Visual Basic (VB) Script
        • Scripting with Python
        • Generating encrypted passwords with iRMC_PWD.exe
pdf background image
download button

Related manuals